Error code library
Wascomat & Electrolux error codes
Newer Wascomat and Electrolux machines with Compass Pro and Clarus Vibe controls show errors as two numbers, a group and a code, for example 11:2 DOOR OPEN. Older Clarus washers show a two-digit number with a text message, older Selecta II dryers show E01 to E99, and Gen 5 / Gen 6 Emerald washers show a number or a number followed by E. We still service all of these generations, so the older codes are listed below as well.
Before resetting any error, find and fix the cause. On frequency-controlled machines the motor control can stay live for about two minutes after power is cut.
- Compass Pro / Clarus Vibe washer codes (group 11)
- Compass Pro dryer codes (group 12)
- Motor control and system codes
- Older Clarus washer codes (program unit, 01–28)
- Older Clarus motor control and door lock codes (31–60)
- Older Clarus washer-dryer program unit codes (73–88)
- Selecta II dryer codes (E01–E99)
- Gen 6 Emerald washer codes (01E–45E)
- Gen 5 Emerald washer codes (01–09)
- Door lock control LED codes (older Clarus / W-series)
Compass Pro / Clarus Vibe washer codes (group 11)
No water
The water level did not reach the set level within the allowed time.
- Make sure water supply valves are open and pressure is adequate.
- Clean the inlet valve filters.
- Check that the drain valve is not letting water out.
Door open
The door-closed switch signal was lost during the program.
- Close the door firmly.
- Technician: check the door switch and its wiring.
Door lock fail
The door-locked signal is missing, or the lock reports locked while the door-closed signal is absent.
- Technician: check the door lock assembly, its microswitches and wiring.
Water temperature sensor low / high
The temperature reading is outside the allowed range, usually an open (low) or shorted (high) sensor.
- Technician: measure the temperature sensor; replace it if out of range.
Water in machine at program end
The level system did not report an empty drum within about three minutes at the end.
- Clear the drain valve and drain line.
- Check the level sensor hose.
No heating / heating timeout
The temperature did not rise enough within the maximum heating time.
- Technician: check heating elements or steam, the heat contactor and the temperature sensor.
Drum overfilled
The water level went above the overfill level.
- Technician: check for a water valve stuck open and the level sensor.
Max time drain
The drum was not empty within about three minutes of draining.
- Look for a clogged drain valve, lint or a sock in the drain, or a blocked trough.
- Technician: test the drain valve motor.
Level sensor or level calibration problem
The control lost the level sensor or the readings are too far from normal to calibrate.
- Technician: check the level sensor hose and sensor, then recalibrate the level system in service mode.
Compass Pro dryer codes (group 12)
Overheat thermostat tripped
The inlet-air or outlet-air overheat thermostat opened.
- Clean the lint filter and lint compartment.
- Check exhaust ducting for restrictions.
- Technician: find why it overheated before resetting.
Air temperature sensor open or shorted
The inlet or outlet air sensor reads open or shorted. These sensors read about 4.8 kΩ at 25°C.
- Technician: measure the sensor and wiring and replace if out of range.
Drying error
The load did not dry correctly in a residual moisture, auto-stop or timed program.
- Check for a clogged lint filter or exhaust.
- Do not overload the dryer.
Gas error
The gas burner failed to ignite or lost flame. Press the gas reset button to retry.
- Make sure gas is on.
- Technician: check gas pressure, ignition and flame sensing.
Vacuum (airflow) switch error
No airflow was detected, the vacuum switch is shorted, or it switches on and off too often.
- Clean the lint filter and exhaust duct.
- Technician: check the fan and the vacuum switch.
Airflow obstructed / clogged filter
The dryer is telling you it needs maintenance.
- Clean the lint filter and lint compartment. If the error stays, call for service.
Motor control and system codes
Machine stop / emergency stop
A stop input or the emergency stop button is active.
- Release the emergency stop and restart.
Drum motor or fan motor overheated
The motor thermal protection tripped.
- Technician: check that the drum or fan turns freely, check bearings and ventilation.
Heatsink too hot
The motor control unit is overheating.
- Technician: check the motor control cooling and that the drum is not binding.
Unbalance
The motor control detected an unbalanced load.
- Redistribute the load and restart.
Motor does not follow
The motor speed does not match what the control asked for.
- Technician: check the belt, motor and tacho / encoder.
Motor control (drive) faults
Power unit, overload, bus, motor protection, encoder and charge circuit errors from the frequency drive.
- Technician: note the exact number, check supply voltage and motor wiring, then the drive.
I/O communication / board mismatch
The main control cannot talk to an I/O board, or the board type does not match.
- Technician: check the communication cable and that the correct board is installed.
Older Clarus washer codes (program unit, 01–28)
No water
The water level was not reached within the set fill time.
- Make sure the water supply valves are open and pressure is adequate.
- Clean the inlet valve filter screens.
- Technician: check the inlet valves and that the drain valve is not letting water out.
Door open
The door-closed signal was lost while a program was running.
- Close the door firmly and restart.
- Technician: check the door-closed microswitch and its wiring.
Door lock fail
The door-locked signal is missing at program start or during the program.
- Technician: check the door lock assembly, lock microswitch and the door lock control.
NTC low temperature
The water temperature sensor reads below about -9°C (15°F). This almost always means an open sensor or a broken wire, not a frozen machine.
- Technician: measure the NTC temperature sensor and its harness, and replace an open sensor.
NTC high temperature
The sensor reads above the allowed maximum, usually a shorted sensor or wiring.
- Technician: measure the sensor and look for a pinched or shorted harness.
Water in machine
There is water above the empty level when a program is started.
- Clear the drain valve and drain line.
- Technician: check the level sensor hose for water or blockage.
Overfilled
The drum filled above a preset level during the program.
- Technician: look for an inlet valve that is letting water by and check the level system.
No heating
The water temperature did not rise as expected within the heating time.
- Technician: check the heating elements, heat contactor, fuses and the temperature sensor.
Klixon (motor overheat) / drum overfilled
On many models the motor's thermal protector (klixon) opened because the motor got too hot. On some program versions 09 means the drum was overfilled.
- Let the machine cool and do not overload it.
- Technician: check that the drum turns freely, check the motor, bearings and the klixon circuit.
Drum not drained
Water is still above the empty level after the drain sequence.
- Clear the drain valve, drain line and trough.
- Technician: test the drain valve motor and level sensor.
Unbalance switch on at program start
The mechanical unbalance switch is already open or closed when the program starts.
- Technician: check the unbalance switch position, adjustment and wiring.
Program failure
The program unit cannot read a valid program from its memory.
- Reload the program or factory settings.
- Technician: replace the program unit if the error returns.
No motor communication
The program unit cannot talk to the motor control.
- Technician: check the communication cable, connectors and supply to the motor control.
Level adjust
The level system has not been calibrated, or calibration values are missing.
- Technician: calibrate the level system in service mode.
Emergency stop
The emergency stop button on the machine has been pressed.
- Release the emergency stop and restart.
- Technician: check the stop circuit if nobody pressed it.
Heating timeout
Heating took longer than the maximum allowed time.
- Technician: check heating elements, contactor and sensor, and supply voltage.
Door lock
The door-locked signal is present while the door-closed signal is missing.
- Technician: check the door switches and lock for a stuck contact.
Start not allowed
An external system (such as a payment or central system) is blocking the start.
- Check the payment system or external start signal.
Master communication
Communication with a master or central system was lost.
- Technician: check the network cable and connection to the central system.
I/O or MCU interlock
The program unit reads from the motor control or I/O board that the interlock is not active.
- Technician: check the door lock interlock circuit and wiring to the motor control.
I/O communication
The program unit lost communication with an I/O board.
- Technician: check the I/O board, communication cable and its supply.
Oil
An oil or lubrication input reported a fault on machines equipped with it.
- Technician: check the oil level input and sensor.
No I/O addressed
No I/O board is addressed in the system at all.
- Technician: check I/O board addressing, cable and power.
Checksum from DLCU
The program unit received bad data from the door lock control unit (DLCU).
- Technician: check the cable between CPU and DLCU, then the DLCU.
Level offset
The level system reading at start is too far off to auto-correct.
- Technician: check the level hose for water or blockage and recalibrate.
CPU/DLCU low levels
The program unit and the DLCU mechanical level monitor disagree about the drum being empty.
- Technician: check the level hose, level sensor and DLCU level guard.
Older Clarus motor control and door lock codes (31–60)
Heat sink too hot
The motor control's heat sink is overheating.
- Technician: clean the motor control and its ventilation, check that the drum is not binding.
Motor too hot
The motor control measured a motor winding resistance that shows the motor is overheated.
- Let it cool. Technician: check motor, bearings and belt, and test the motor windings.
No interlock
The motor control is not getting interlock voltage (230 V) from the door lock, so it will not drive the motor.
- Technician: check the door lock interlock output and wiring to the motor control.
Motor short circuit
The motor control saw a current spike that indicates a short in the motor or motor cable.
- Technician: check motor cable and connectors, and measure windings to ground.
Interlock hardware
Fault in the interlock circuit inside or into the motor control.
- Technician: check interlock wiring, then the motor control.
Low DC voltage
The DC bus inside the motor control dropped too low, usually from low supply voltage.
- Technician: measure supply voltage under load and check connections and fuses.
High DC voltage
The DC bus is too high, from high supply voltage or energy coming back from the motor during braking.
- Technician: measure supply voltage and check the braking circuit.
No parameters set in MCU
The motor control does not have the correct parameter set for this machine.
- Technician: load the correct parameters for the machine model.
Motor not following
The motor speed does not match what the motor control commanded.
- Technician: check the belt, motor, tacho and the load.
Checksum from CPU
The door lock control unit (DLCU) received bad data from the program unit.
- Technician: check the CPU-to-DLCU cable and connections.
Charge circuit
The DLCU's arming circuit for the door lock coil did not charge or discharge as expected.
- Technician: check the door lock coil and DLCU.
CPU/DLCU high levels
The program unit and the DLCU disagree about a high water level.
- Technician: check the level hose, level sensor and DLCU level guard.
Tacho, no set signal
The DLCU sees tacho pulses (drum turning) without a motor run signal.
- Technician: check the tacho / rotation sensor and the motor control run signal.
Set speed with door open
A motor run signal was seen while the door was unlocked.
- Technician: check door lock signals and the motor control.
Set signal, no tacho
The motor control says the motor runs but the DLCU gets no tacho pulses.
- Technician: check the belt, tacho / rotation sensor and its wiring.
Actuator circuit
The DLCU detected a fault in the door lock actuator coil circuit.
- Technician: check the door lock actuator coil, harness and DLCU output.
Older Clarus washer-dryer program unit codes (73–88)
Inlet / outlet temperature sensor shorted
A dryer air temperature sensor or its wiring is shorted.
- Technician: measure the sensor and wiring and replace if shorted.
Fan motor / drum motor too hot
The thermal protector in the fan or drum motor opened.
- Clean lint from the motor and fan area.
- Technician: check the motor and its protector circuit.
External error
An external input such as a fire or safety signal stopped the machine.
- Technician: check the external input wiring.
Machine overheated
An overheat protection thermostat opened.
- Clean lint filter and exhaust.
- Technician: find the cause before resetting the thermostat.
Filter lid open
The lint filter lid or drawer is not closed.
- Close the filter lid; check the lid switch.
Incorrect programming
A dryer program parameter is wrong or missing.
- Technician: correct the programming or reload factory settings.
Drying error
The load did not dry within the maximum time for a moisture, autostop or timed program.
- Clean the lint filter and check exhaust airflow.
- Do not overload.
No gas flame detected
The burner did not light or lost its flame.
- Make sure gas is on.
- Technician: check gas pressure, ignition and flame sensing.
No vacuum / vacuum sensor shorted
The airflow (vacuum) switch did not close, or was already closed at start.
- Clean the lint filter and exhaust duct.
- Technician: check the fan and the vacuum switch.
Inlet / outlet sensor open circuit
A dryer air temperature sensor or its wiring is open.
- Technician: reconnect or replace the sensor or harness.
Selecta II dryer codes (E01–E99)
Inlet air temperature too high
The air entering the drum is hotter than allowed.
- Clean the lint filter and lint compartment.
- Check the exhaust duct for restriction.
- Technician: check the burner or heater control.
Outlet air temperature too high
The air leaving the drum is hotter than allowed, usually from poor airflow.
- Clean the lint filter and exhaust.
- Technician: check the fan and the outlet sensor.
Inlet air sensor shorted
The inlet air thermistor or its wiring has shorted.
- Technician: measure the thermistor and harness and replace if shorted.
Outlet air sensor shorted
The outlet air thermistor or its wiring has shorted.
- Technician: measure the thermistor and harness and replace if shorted.
Blower (fan) motor thermal protection open
The thermal switch in the blower motor, or its harness, is open. The fan motor overheated or the circuit is broken.
- Clean lint off the blower motor and fan wheel.
- Technician: check the fan motor, its protector and harness.
Drum motor thermal protection open
The thermal switch in the drum (drive) motor, or its harness, is open.
- Technician: check that the drum turns freely, check drum rollers / bearings, motor and harness.
Overheat protection thermostat open
One of the inlet or outlet air safety thermostats opened because the dryer overheated. This is a safety shutdown, usually caused by lint buildup or poor exhaust airflow.
- Clean the lint filter, lint compartment and burner area.
- Check the exhaust duct and outside damper for blockage.
- Technician: find the cause before resetting the thermostat and verify burner and fan operation.
Lint drawer
The lint drawer must be emptied before the dryer will start.
- Empty and clean the lint drawer and close it fully.
Setting error
A program setting is wrong or missing.
- Technician: check programming or reload default settings.
Drying error (RMC / autostop)
The maximum time for a residual moisture (RMC) or autostop program was exceeded. Non-coin models only.
- Clean the lint filter and check exhaust.
- Do not overload.
Drying time too long
The requested drying time is longer than allowed when connected to a payment system.
- Check the payment system and price settings.
Gas error
No flame was detected on a gas dryer.
- Make sure the gas supply is on.
- Press the gas reset if fitted and retry.
- Technician: check gas pressure, igniter, flame sensor and gas valve.
Vacuum (airflow) switch did not close
The vacuum switch did not close within 5 seconds after the dryer started, so the control thinks there is no airflow. Most often a clogged lint filter, blocked exhaust or a fan problem.
- Clean the lint filter and lint compartment.
- Check the exhaust duct for lint, crushing or a stuck damper.
- Technician: check the fan wheel, fan motor, vacuum switch and its hose.
Vacuum switch already closed
The vacuum switch was already closed when the dryer was started, usually a stuck switch or a draft in the exhaust.
- Technician: check the vacuum switch and its hose, and the exhaust installation.
Inlet / outlet sensor disconnected
The inlet or outlet air thermistor, or its wiring, is open.
- Technician: reconnect or replace the sensor or harness.
CMIS / LM10 communication
The dryer was taken out of service from the PC program, or the PC did not poll the dryer in time.
- Check the central PC system and network connection.
Internal communication error
The user module (display) is not receiving communication from the main board.
- Technician: check the cable between the display module and main board.
Gen 6 Emerald washer codes (01E–45E)
Water level not reached
The water level acknowledgement was not received within the set time.
- Check water supply, inlet filters and pressure.
Door closed / door locked switch
Missing door-closed or door-locked signal, or locked without closed.
- Close the door firmly.
- Technician: check door switches and the lock.
Temperature sensor open / shorted
The sensor reads below about -5°C (open) or above 98°C (shorted).
- Technician: measure the temperature sensor and harness.
Water level too high
Water above the safety level at start, during the program, or after draining.
- Clear the drain.
- Technician: check for a leaking inlet valve and the level system.
No heating or slow heating
The water heated too slowly or not at all.
- Technician: check heating elements, contactor and sensor.
Unbalance switch
The mechanical unbalance switch is always activated, or triggered with the motor stopped.
- Technician: check unbalance switch adjustment and wiring.
Program memory / processor error
The program unit cannot read its program memory, or a processor configuration error.
- Technician: reload or replace the program unit.
No communication with RDC card
The program unit cannot communicate with the motor drive (RDC) card.
- Technician: check the cable and power to the RDC card.
Level system not calibrated
The water level system needs calibration, or the reading is too far off to auto-correct.
- Technician: check the level hose and calibrate the level system.
CALCAD 4400 system
The CALCAD central system does not allow the program, or communication with it was lost.
- Check the CALCAD system and connection.
Motor thermal protector
The RDC card reports that the motor's thermal protector triggered.
- Technician: check motor, bearings and belt.
Tacho pulses missing
The RDC card sees no tacho pulses at the requested speed.
- Technician: check belt, motor and tacho.
Gen 5 Emerald washer codes (01–09)
Water level too low
The washer did not reach its water level. You can restart after fixing it.
- Open the water taps.
- Check the level control and the drain valve for leaks.
Door lock fault
The door did not lock. You can restart after fixing it.
- Open and lock the door again.
- Technician: replace the lock if needed.
Temperature sensor open / shorted
Break (03) or short circuit (04) in the temperature sensor or its wiring.
- Technician: test and replace the sensor or harness.
Water in drum at start
Water was found in the drum at the start of the cycle.
- Clear a clogged drain valve or drain line.
Software error
Control software error.
- Turn power off and on and try again; call for service if it repeats.
Too much water before extraction
Water still in the drum at the start of an extract.
- Clear the drain valve and drain line.
Door lock control LED codes (older Clarus / W-series)
Water in drum with door lock open
The level guard reports water in the drum while the door lock is open, so the door cannot be locked.
- Drain the machine.
- Technician: check the level guard and its input on the door lock control.
Motor running with door lock open
The motor control says the motor is running while the door lock is open.
- Technician: check the motor control run signal to the door lock control.
No rotation sensor signal
The motor control says the motor is running but the rotation sensor gives no signal.
- Technician: check the belt, rotation sensor and its wiring.
Rotation without motor signal
The rotation sensor says the drum is turning but there is no motor signal.
- Technician: check the rotation sensor and motor control signal.
Door lock drive circuit error
Fault in the door lock output, the lock itself or its cable harness.
- Technician: check the door lock and harness.
Internal door lock control error
The door lock control board has an internal fault.
- Technician: replace the door lock control.
No codes on this page match. Try the full library search or call us.
These explanations are general guidance written by CLS from manufacturer service documentation, and code meanings can vary by control version. Always confirm with the manual for your exact model. Disconnect power (and gas or steam) before opening any panel. Repairs inside the machine should be done by a qualified technician.