Error code library
Continental Girbau error codes
Continental Girbau E-Series washers (Logi, LogiPro and vended controls) and HS / H2 hardmount washers show alarms on the display as “ALn” followed by a letter or code. Inverter (drive) problems show as VAR, U- or UA codes. Running the machine's Test Mode is the fastest way to confirm what is wrong.
Machine alarms
Water fill alarm
The machine did not reach the required water level in the allowed time.
- Make sure water supply valves are open.
- Clean the inlet valve filters and check pressure.
- Technician: check the drain valve for leaking by and the level sensor tube for a split or blockage.
Drain alarm
The machine did not drain in time.
- Clear the drain valve or drain pump of debris.
- Check the building drain.
Water level alarm
Water level problem, often linked to drain or level sensor.
- Check drain valve function.
- Technician: test the water level sensor.
High water level
Water rose above the required level in wash, or did not drain fast enough in spin.
- Technician: check for a water valve stuck open, and clear the drain.
High bath temperature
The bath is hotter than allowed.
- Press start to resume. If it repeats, check the hot water supply temperature.
Heating system alarm
The machine did not reach the set temperature.
- Technician: check the heating element or steam supply and configuration.
Temperature probe alarm
The temperature probe is faulty.
- Technician: measure the probe resistance (it is an NTC sensor) and replace if out of range.
Balance switch alarm
The machine detected an unbalanced condition.
- Load the machine properly (at least half full, mixed items).
- Check that the machine is properly installed and level.
- Technician: check the balance switch.
Door closed or door lock fault
The door lock is not confirming closed and locked.
- Technician: check door lock adjustment and assembly. On HS-5008, a blown F2 fuse on the processor board can also cause it.
Emergency stop
The emergency stop switch is pressed.
- Release the E-stop switch.
Identification alarm
The control does not recognize the machine identification.
- Technician: check the ID jumpers on the processor board.
Inverter (drive) alarms
Inverter communication error
No communication between the inverter and the processor. The inverter needs power and a good communication cable.
- Technician: check inverter power, fuses and inverter relay, the communication harness (clean contacts), motor discharge resistor and earth ground.
Over-current
Fast, high rise of motor current during acceleration, braking or normal running.
- Check that the basket turns freely.
- Check the drain valve or pump for debris.
- Technician: clean the inverter heatsink, check motor windings and amperage on each leg.
Motor overheat
The motor klixons (thermal overloads) opened.
- Technician: check for basket drag, bad motor bearings and inverter cooling; test motor windings.
High DC bus voltage
Inverter DC voltage is higher than allowed.
- Technician: verify incoming voltage is within range and check for a loose neutral.
Inverter overheat
The inverter is above its operating temperature. Over-sudsing can contribute.
- Use the right amount of low-suds detergent.
- Technician: clean the inverter, confirm the fan runs and the cover is installed.
Inverter / processor mismatch or parameters
Wrong ID plug, wrong inverter or firmware, or inverter parameters not loaded.
- Technician: confirm correct parts, then download inverter parameters with the door closed.
Input voltage out of range
Supply voltage to the inverter is too low or too high.
- Technician: measure supply voltage and check for loose or poorly crimped connections.
Open motor phase / motor not connected
A motor phase was lost or the motor disconnected during operation.
- Technician: check motor connections and windings.
Inverter over-current, overload, overheat or motor overheat
Excessive motor current or heat.
- Technician: check basket and motor spin freely, motor bearings, wiring and grounding, and clean the inverter.
Inverter internal failure
An internal inverter component has failed.
- Technician: verify the machine is above freezing and wiring is good, then replace the inverter.
Communication or startup failure
Inverter lost communication or did not initialize at power-up.
- Technician: check inverter input voltage and the harness to the processor; clean the connector.
H20 Series inverter alarms (A- codes)
Over current (inverter OC1–OC3)
Fast, high rise of motor current.
- Technician: check the motor and inverter output wiring for a short or ground, and the door lock safety system.
Inverter relay K-2 failure
The inverter relay did not respond.
- Technician: check wiring, the washer processor and inverter parameters.
Over voltage in DC link (OU1–OU3)
The inverter DC bus voltage went too high.
- Technician: check the supply voltage, inverter parameters, motor and its connections.
Low voltage
Supply voltage to the inverter is too low.
- Technician: check the supply voltage and the KA1 relay.
Input phase loss
A supply phase is missing or the phases are unbalanced.
- Technician: check fuses, supply phases and wiring between the KA1 relay and inverter.
Inverter overheating (OH1 / OH3)
The inverter is too hot.
- Clean the inverter filter.
- Technician: check the inverter fan and the room temperature.
Motor overheating (OH2)
The motor thermal protector (klixon) opened.
- Technician: check the motor, bearings, cooling fan and supply voltage.
Braking resistor overheating
The braking resistor overheated.
- Technician: check inverter parameters and the braking resistor.
Motor overload (OL / OLU)
Motor current higher than allowed for too long.
- Check that the drum turns freely and the drain is clear.
- Technician: check the motor, connections and drum bearings.
Inverter parameter error
The inverter information or parameters are wrong.
- Technician: reload the correct inverter parameters.
Communication failure
The processor and inverter are not communicating.
- Technician: check the communication cable, 5 VDC from the processor, inverter supply, processor and inverter.
No codes on this page match. Try the full library search or call us.
These explanations are general guidance written by CLS from manufacturer service documentation, and code meanings can vary by control version. Always confirm with the manual for your exact model. Disconnect power (and gas or steam) before opening any panel. Repairs inside the machine should be done by a qualified technician.